M5200 Pressure Transmitter

Pressure Transmitter Manufacturer, Supplier and Exporter

CPI Technology Private Limited offers the M5200 Pressure Transmitter, part of the MEAS 5200 Series, for reliable pressure measurement in compatible industrial and original equipment manufacturing applications.

The transmitter is available for gauge, absolute, vacuum and compound pressure measurement. Depending on the selected configuration, it can measure gauge pressure from 0–0.1 bar up to 0–1000 bar, compound pressure from -760 mmHg–0 up to 0–30 bar, and absolute pressure from 0–1 bar up to 0–30 bar.

The unit provides selectable analogue outputs, including 4–20 mA DC, 0–5 V, 0–10 V and 1–5 V. Its standard power supply is 24 V DC, with an operating supply range of 18–36 V DC.

Designed primarily for original equipment manufacturers with low- to medium-volume requirements, the M5200 series can also be considered for customized configurations where the order volume and application justify a modified design.

CPI Technology Private Limited serves industrial buyers as a manufacturer, supplier and exporter of pressure instruments from Ahmedabad, Gujarat, India.

What Is a Pressure Transmitter?

A pressure transmitter is an industrial measuring instrument that converts applied pressure into a proportional electrical output signal.

The pressure applied through the process connection acts on the transmitter’s sensing diaphragm. The sensing assembly converts the pressure input into an electrical signal that can be transmitted to compatible control and monitoring equipment.

Depending on the selected output, the signal may be connected to:

  • Process indicators

  • Programmable logic controllers

  • Distributed control systems

  • Data-acquisition systems

  • Pressure controllers

  • Machine control panels

  • Alarm and monitoring systems

  • OEM equipment control circuits

Unlike a local mechanical pressure gauge, a transmitter allows the measured pressure value to be communicated electrically to another device.

This makes it suitable for applications where pressure must be displayed remotely, recorded, used for control logic or integrated into an automated process.

The M5200 series offers several measurement principles and pressure ranges, making it suitable for different OEM and industrial pressure-measurement requirements.

M5200 Pressure Transmitter Overview

The M5200 belongs to the MEAS 5200 Series and is geared toward OEM customers requiring low- to medium-volume quantities.

The product is offered with multiple pressure-reference options:

  • Gauge pressure

  • Absolute pressure

  • Vacuum pressure

  • Compound pressure

The selected pressure type must match the actual process requirement.

A gauge-pressure model measures pressure relative to the surrounding atmospheric pressure. An absolute-pressure model measures pressure relative to an absolute vacuum reference. A compound-pressure model is suitable where the measured pressure may move below and above atmospheric pressure.

The transmitter provides an accuracy of ±0.25% of full scale and can withstand an overload of three times full scale without damage, according to the supplied product specification.

The sensing diaphragm is manufactured from SS 316L. The listed wetted-part materials are stainless steel and PH 17-4.

The operating-temperature range is specified as -40°C to +125°C.

Key Features

  • Suitable for gauge, absolute, vacuum and compound pressure measurement.

  • Gauge-pressure ranges from 0–0.1 bar up to 0–1000 bar.

  • Compound-pressure ranges from -760 mmHg–0 up to 0–30 bar.

  • Absolute-pressure ranges from 0–1 bar up to 0–30 bar.

  • Accuracy of ±0.25% of full scale.

  • Overload capacity of three times full scale without damage.

  • Available with 4–20 mA DC current output.

  • Available with 0–5 V or 0–10 V voltage output.

  • Available with 1–5 V output.

  • Power-supply range from 18 to 36 V DC.

  • Standard power supply of 24 V DC.

  • DIN electrical connector.

  • SS 316L diaphragm.

  • Stainless steel and PH 17-4 wetted parts.

  • Multiple process-connection options.

  • Operating-temperature range from -40°C to +125°C.

  • Developed primarily for OEM customers with low- to medium-volume requirements.

  • Additional or customized configurations may be available depending on application and order volume.

Technical Specifications

Specification Details
Product Pressure Transmitter
Model M5200
Series MEAS 5200 Series
Pressure Principle Gauge, Absolute, Vacuum and Compound
Gauge-Pressure Range 0–0.1 bar to 0–1000 bar
Compound-Pressure Range -760 mmHg–0 to 0–30 bar
Absolute-Pressure Range 0–1 bar to 0–30 bar
Overload Capacity 3 × full scale without damage
Accuracy ±0.25% of full scale
Current Output 4–20 mA DC
Voltage Outputs 0–5 V, 0–10 V and 1–5 V
Power Supply 18–36 V DC
Standard Power Supply 24 V DC
Electrical Connection DIN connector
Process Connections G 1/4 inch, 7/16 UNF, TC End Female and other connections available
Diaphragm Material SS 316L
Wetted Parts Stainless steel, PH 17-4
Operating Temperature -40°C to +125°C
Primary Customer Segment OEM customers requiring low- to medium-volume quantities
Customization Custom designs and additional configurations may be possible depending on volume and application

Pressure Measurement Types

Selecting the correct pressure-reference type is one of the most important steps when ordering a transmitter.

Gauge Pressure

Gauge pressure is measured relative to the surrounding atmospheric pressure.

The M5200 gauge-pressure range begins at 0–0.1 bar and extends up to 0–1000 bar, depending on the selected model and configuration.

Gauge-pressure measurement may be selected where the process pressure is required relative to local atmospheric conditions.

The buyer should specify the exact minimum and maximum pressure range required.

Absolute Pressure

Absolute pressure is measured relative to an absolute vacuum reference.

The stated absolute-pressure range for the M5200 series begins at 0–1 bar and extends up to 0–30 bar.

Absolute measurement may be required where changes in atmospheric pressure should not affect the reference point of the measurement.

The final range must be selected according to the process requirement.

Vacuum Pressure

Vacuum measurement applies where the process pressure is below atmospheric pressure.

The exact vacuum configuration and scale should be stated in the enquiry so that the required model can be reviewed.

Compound Pressure

Compound-pressure measurement is used where the process can operate below and above atmospheric pressure.

The supplied compound range begins at -760 mmHg–0 and extends up to 0–30 bar.

A compound model can therefore be considered where both vacuum and positive pressure conditions may occur within the same process or equipment cycle.

Output Signal Options

The M5200 series is available with current and voltage output options.

4–20 mA DC Output

The 4–20 mA current signal is commonly used in industrial process instrumentation.

It can be connected to compatible receiving equipment such as:

  • PLC analogue-input modules

  • Process indicators

  • Controllers

  • Data loggers

  • DCS input cards

  • Remote monitoring systems

The complete measuring loop must be designed according to the selected transmitter configuration, power supply and receiving-device requirements.

0–5 V Output

A 0–5 V output may be selected where the receiving equipment accepts a corresponding voltage input.

The wiring arrangement and supply requirements must be checked before installation.

0–10 V Output

A 0–10 V signal may be used with compatible automation, monitoring or control devices.

The buyer should confirm that the receiving input is designed for the same voltage range.

1–5 V Output

The M5200 series is also available with a 1–5 V output.

The required output should be clearly stated when requesting a quotation because the output configuration affects compatibility with the connected control system.

Power-Supply Requirement

The specified power-supply range is 18–36 V DC, with 24 V DC as the standard supply.

The installed power source must remain within the stated range and must be compatible with the selected output configuration.

Before commissioning, the instrumentation engineer should verify:

  • Supply-voltage level

  • Correct polarity

  • Receiving-device compatibility

  • Field wiring

  • Electrical connector

  • Loop resistance, where applicable

  • Grounding and shielding practices

  • Control-panel termination

A supply voltage outside the approved range should not be applied to the transmitter.

Accuracy and Overload Capability

The stated accuracy of the M5200 is ±0.25% of full scale.

Accuracy expressed as a percentage of full scale is related to the selected measuring span. Therefore, selecting a pressure range much higher than the actual operating requirement may reduce the practical resolution available around the normal pressure point.

For example, a process operating at relatively low pressure should not automatically be assigned a very high-range transmitter unless the maximum process and upset conditions require it.

The transmitter also has a stated overload capacity of three times full scale without damage.

This overload rating provides a defined margin against pressure excursions. However, the overload rating should not be treated as the normal operating range.

The transmitter should be selected so that the expected operating pressure remains within the specified measuring range.

Construction and Wetted Materials

The M5200 transmitter has an SS 316L diaphragm.

The listed wetted parts are:

  • Stainless steel

  • PH 17-4

Wetted parts are the transmitter components exposed to the process medium.

Process-medium compatibility must therefore be checked against the stated materials before finalizing the instrument.

The buyer should provide details of the medium, including:

  • Liquid or gas

  • Chemical name

  • Concentration

  • Operating temperature

  • Possibility of corrosion

  • Presence of suspended solids

  • Viscosity

  • Cleaning or sterilization conditions

  • Pressure pulsation

No assumption should be made regarding material compatibility solely because the diaphragm is stainless steel.

Process-Connection Options

The available process connections include:

  • G 1/4 inch

  • 7/16 UNF

  • TC End Female

  • Other connections subject to availability

The required process connection should match the equipment tapping point, manifold, adapter or process piping arrangement.

Using the correct connection helps achieve proper mechanical installation and reduces the need for unnecessary adapters.

When requesting a quotation, the buyer should clearly specify:

  • Connection type

  • Thread standard

  • Male or female requirement

  • Connection size

  • Sealing arrangement

  • Orientation requirement

  • Any special process interface

Additional process configurations may be possible, but their availability should be confirmed before order placement.

Electrical Connection

The standard electrical connection is a DIN connector.

A DIN connector provides a defined connection interface between the transmitter and the field cable.

During installation, the engineer should verify:

  • Terminal identification

  • Cable entry

  • Polarity

  • Connector sealing

  • Correct tightening

  • Cable support

  • Earthing arrangement

  • Environmental protection requirement

The connector must be assembled according to the supplied wiring instructions.

Applications

The M5200 series can be considered for compatible pressure-measurement requirements in industrial machinery and OEM equipment.

Typical application areas may include:

  • Hydraulic equipment

  • Pneumatic systems

  • Industrial machinery

  • Pumps and pumping skids

  • Compressors

  • Pressure-monitoring panels

  • Process equipment

  • Water-treatment systems

  • Utility equipment

  • Machine automation

  • Test and measurement systems

  • Filtration equipment

  • Pressure-control systems

  • Packaging machinery

  • Industrial skids

  • OEM assemblies

  • Mobile equipment

  • Fluid-power systems

  • Process monitoring

  • Remote pressure indication

Actual suitability depends on the selected pressure range, output, process connection, media compatibility, temperature and installation environment.

Industries Served

The transmitter may be considered by buyers in industries such as:

  • Industrial machinery manufacturing

  • Hydraulic-system manufacturing

  • Pneumatic-equipment manufacturing

  • Water and wastewater treatment

  • Chemical processing

  • Pharmaceutical equipment

  • Food-processing machinery

  • Oil and gas equipment

  • Power and utility systems

  • Pump manufacturing

  • Compressor manufacturing

  • Factory automation

  • Process skid manufacturing

  • Engineering procurement and construction

  • Test-rig manufacturing

  • Control-panel manufacturing

Each application should be reviewed against the confirmed technical specification.

OEM-Focused Design

The MEAS 5200 Series is geared toward OEM customers with low- to medium-volume requirements.

OEM buyers often require a transmitter that can be integrated into a machine, skid or manufactured assembly with consistent technical and commercial specifications.

The M5200 offers several parameters that can be selected according to the equipment design:

  • Pressure-reference type

  • Measuring range

  • Output signal

  • Process connection

  • Electrical connection

  • Power supply

  • Wetted materials

Where the application and required quantity justify it, a custom M5200 design may be considered.

Additional configurations not listed in the standard product information may also be available or technically possible.

Buyers requiring a special configuration should submit complete application and annual-volume details for review.

Custom-Configuration Possibilities

The supplied product information states that custom designs may be provided where the volume and application warrant.

Customization should not be assumed to be standard or automatically available.

A custom request should include:

  • Required pressure type

  • Exact measuring range

  • Maximum overload

  • Output signal

  • Power supply

  • Process connection

  • Electrical connection

  • Process medium

  • Operating temperature

  • Installation environment

  • Required quantity

  • Estimated annual volume

  • Sample requirement

  • Testing requirement

  • Documentation requirement

The feasibility of a modified design is subject to technical and commercial evaluation.

Selecting the Correct Measuring Range

Correct range selection improves the usefulness of the measurement and reduces the risk of over-ranging the transmitter.

The buyer should identify:

  • Minimum operating pressure

  • Normal operating pressure

  • Maximum operating pressure

  • Start-up pressure

  • Shutdown pressure

  • Pressure surges

  • Vacuum conditions

  • Pressure pulsation

  • Required pressure unit

The selected full-scale range should accommodate the maximum expected process pressure while remaining close enough to the normal operating range to provide useful measurement resolution.

The overload capacity should be considered an equipment-protection parameter, not a substitute for correct range selection.

Buyer Benefits

Wide Pressure-Range Availability

The M5200 series covers low, medium and high gauge-pressure ranges, along with absolute and compound configurations.

This allows buyers to select a transmitter closer to the actual application requirement.

Multiple Output Options

Current and voltage outputs are available for integration with different control and monitoring systems.

Defined Accuracy

The ±0.25% full-scale accuracy provides engineering and procurement teams with a clear performance parameter for technical evaluation.

High Overload Rating

The specified three-times-full-scale overload capability provides protection against pressure excursions within the declared limit.

Stainless-Steel Diaphragm

The SS 316L diaphragm supports use with compatible industrial media.

Material compatibility must still be confirmed for each application.

OEM Configuration Support

The product is intended for OEM customers and may be offered in customized configurations when volume and application conditions justify development.

Broad DC Supply Range

The 18–36 V DC supply range, with 24 V DC standard, supports integration into compatible industrial control systems.

Multiple Process Connections

Standard and additional process-interface options allow the transmitter to be considered for different mechanical installation requirements.

Information Required for Quotation

To receive a technically correct and commercially relevant quotation, buyers should provide:

  • Pressure type: gauge, absolute, vacuum or compound

  • Required pressure range

  • Pressure unit

  • Normal operating pressure

  • Maximum pressure

  • Expected surge or overload pressure

  • Required output signal

  • Available power supply

  • Process-medium details

  • Process temperature

  • Required process connection

  • Electrical-connection requirement

  • Quantity

  • Annual volume for OEM projects

  • Application or equipment name

  • Installation environment

  • Delivery location

  • Export destination, where applicable

Incomplete pressure or application information may result in incorrect instrument selection.

Why Choose CPI Technology Private Limited?

CPI Technology Private Limited serves industrial customers as a process instrument manufacturer, supplier and exporter from Ahmedabad, Gujarat, India.

We work with factory engineering teams, original equipment manufacturers, automation companies, contractors, consultants and procurement departments.

Application-Oriented Selection

Pressure-transmitter selection depends on more than the maximum pressure.

Our technical review considers the measuring principle, pressure range, output, power supply, connection and process medium stated by the buyer.

Manufacturer and Supplier in Ahmedabad

Our Ahmedabad location supports industrial customers across Gujarat and other manufacturing regions in India.

Buyers can submit their equipment data sheet, instrument schedule, bill of quantities or project specification for review.

OEM Supply Support

The M5200 series is intended for OEM requirements, including low- to medium-volume projects.

Where customization is required, the application details and expected volume can be submitted for feasibility review.

Export Supply from India

CPI Technology Private Limited supports export enquiries from industrial distributors, machinery manufacturers, engineering contractors and project companies.

International buyers should provide the destination, quantity, technical configuration and required documentation.

Structured Technical Documentation

We provide organized specifications so that engineering and procurement teams can compare pressure range, accuracy, output, material and connection requirements before placing an order.

Pressure Transmitter Supplier in Gujarat

Industrial customers in Ahmedabad, Vadodara, Ankleshwar, Bharuch, Surat, Vapi, Rajkot and other manufacturing locations can submit enquiries for pressure-measurement instruments.

We serve:

  • Process plants

  • Machinery manufacturers

  • Hydraulic-equipment companies

  • Pump and compressor manufacturers

  • Automation contractors

  • Control-panel builders

  • OEM equipment manufacturers

  • Project procurement companies

  • Engineering consultants

  • Industrial distributors

The exact M5200 configuration will depend on the submitted application and measurement requirements.

Request a Quotation

For the M5200 Pressure Transmitter price and availability, send us the required pressure type, measuring range, output signal, power supply, process connection, medium, quantity and delivery location.

For customized OEM requirements, also provide the expected annual quantity and complete application details.

CPI Technology Private Limited will review the requirement and prepare a suitable technical and commercial offer.

Frequently Asked Questions

1. What pressure types are available in the M5200 series?

The M5200 is available for gauge, absolute, vacuum and compound-pressure measurement.

2. What is the gauge-pressure range?

The stated gauge-pressure range begins at 0–0.1 bar and extends up to 0–1000 bar, depending on the selected configuration.

3. What is the accuracy of the Pressure Transmitter?

The specified accuracy is ±0.25% of full scale.

4. Which output signals are available?

Available outputs include 4–20 mA DC, 0–5 V, 0–10 V and 1–5 V.

5. What power supply is required?

The transmitter operates from 18–36 V DC, with 24 V DC specified as the standard supply.

6. What process connections are available?

Listed connections include G 1/4 inch, 7/16 UNF and TC End Female. Other connection options may also be available.

7. Can the M5200 be customized for OEM applications?

Yes. A custom design or additional configuration may be considered where the application and required volume justify it. Feasibility must be confirmed through a technical review.

Image SEO Recommendations

Image File Name Suggestions

  • m5200-pressure-transmitter.jpg

  • meas-5200-series-pressure-transmitter.jpg

  • industrial-pressure-transmitter-4-20ma.jpg

  • pressure-transmitter-manufacturer-ahmedabad.jpg

  • ss316l-diaphragm-pressure-transmitter.jpg

ALT Text Suggestions

  • M5200 Pressure Transmitter with DIN connector

  • MEAS 5200 Series industrial pressure transmitter

  • Pressure Transmitter with 4–20 mA output

  • Pressure Transmitter manufacturer in Ahmedabad

  • M5200 transmitter with SS 316L diaphragm

Schema Recommendations

Product Schema

Schema Property Recommended Value
Name M5200 Pressure Transmitter
Model M5200
Series MEAS 5200 Series
Category Industrial Pressure Instrument
Pressure Types Gauge, Absolute, Vacuum and Compound
Gauge Range 0–0.1 bar to 0–1000 bar
Compound Range -760 mmHg–0 to 0–30 bar
Absolute Range 0–1 bar to 0–30 bar
Accuracy ±0.25% of full scale
Overload 3 × full scale without damage
Output 4–20 mA DC, 0–5 V, 0–10 V and 1–5 V
Power Supply 18–36 V DC, standard 24 V DC
Electrical Connection DIN connector
Process Connection G 1/4 inch, 7/16 UNF, TC End Female and other available connections
Diaphragm SS 316L
Wetted Parts Stainless steel and PH 17-4
Operating Temperature -40°C to +125°C
Manufacturer CPI Technology Private Limited
Image Add the final product image URL
SKU or MPN Add only when a verified code is available
Offer Add confirmed price, currency and availability
Quote Now

Quote now for more about Industrial Process Instruments